One weakness of the Stag PPZ device programmer is its built-in display. A working display is required to configure the serial settings for remote mode used by the StagCom 1, StagCom 3 and StagView programs.
The video board in the PPZ is separate from the digital boards and connected using a cable with a 3-pin plug. A fellow PPZ owner designed a circuit which converts the signals from the digital boards into a composite video signal for a TV or monitor. Using this I can now document the key presses required to configure the PPZ if the display is not working.
Turn key to System Menu position
Key press
|
Menu displayed/ Setting
|
Notes
|
'A'
|
'Set System'
|
|
'1'
|
'Set Interface Hardware'
|
|
'Left' x 2
|
'Serial I'
|
|
'Down'
|
'Baud Rate'
|
|
'Left' x 15
|
'38400'
|
|
'Right' x 1
|
'19200'
|
Highest baud rate that works
|
'Down'
|
'Word Length'
|
|
'Right' x 2
|
'8'
|
|
'Down'
|
'Parity'
|
|
'Left' x 2
|
'Off'
|
|
'Down'
|
'Stop Bits'
|
|
'Left'
|
'1'
|
|
'Enter'
|
'Set System'
|
|
'2'
|
'Set I/O Software'
|
|
'Down'
|
'Cntrl Z'
|
|
'Left'
|
'Off'
|
|
'Enter'
|
'Set System'
|
|
'4'
|
'Miscellaneous'
|
|
'Down'
|
'Remote I/O'
|
|
'Left' x 2
|
'Serial I'
|
|
'Down'
|
'Pass-Through'
|
|
'Left'
|
'Off'
|
|
'Enter'
|
'Set System'
|
Turn key to Remote position and press 'Reset'
Turn key to System Menu position
Key press
|
Menu displayed/ Setting
|
Notes
|
'A'
|
'Set System'
|
|
'1'
|
'Set Interface Hardware'
|
|
'Left' x 2
|
'RS232C 1'
|
|
'Down'
|
'Baud Rate'
|
|
'Left' x 15
|
'38400'
|
|
'Right' x 1
|
'19200'
|
Highest baud rate that works
|
'Down'
|
'Word Length'
|
|
'Right' x 2
|
'8'
|
|
'Down'
|
'Parity'
|
|
'Left' x 2
|
'Off'
|
|
'Down'
|
'Stop Bits'
|
|
'Left'
|
'1'
|
|
'Enter'
|
'Set System'
|
|
'2'
|
'Set Interface Software'
|
|
'Down'
|
'Cntl/z at Eof'
|
|
'Left'
|
'Off'
|
|
'Enter'
|
'Set System'
|
|
'4'
|
'Miscellaneous'
|
|
'Down'
|
'Remote I/O'
|
|
'Left' x 2
|
'RS232C 1'
|
|
'Down'
|
'Passthrough'
|
|
'Left'
|
'Off'
|
|
'Enter'
|
'Set System'
|
Turn key to Remote position and press 'Reset'